This is the manual for the controller in Mosquito-Pro™ misting systems. Mosquito-Pro™ is designed and built by Mosquito Management Systems in Houston. You can also download the PDF. For help with a system, call us at (832) 778 - 6366.
Main system features
- Easy-to-use LCD interface, with an intuitive keypad layout and menu system
- Quick installation and programming: up to 80 sprays a day
- Standby mode
- Proven remote control system
- Full statistics menu: displays current usage, estimates the refill date and saves on unnecessary refills
- Controls 2 separate zones, doubling system capacity at low added cost
- Controls up to 4 systems with one remote
- Franchise refill lockout code
- Sprays selectively by month and day: full flexibility for vacation homes, and automatic shutoff in winter
- Programmable for future needs or expansion
Panel buttons
- OK: selects menu items and confirms input.
- X: returns to the main menu and cancels input.
- UP / DOWN: scroll through menu choices and toggle AM/PM.
- 0–9: enter numbers and toggle yes/no questions.
Main menu
- Press OK to spray: the start of the main menu. OK sprays for the time set by Set duration; X cancels the spray early.
-
Add spray time: adds a time of day to spray. Enter the time with the number pad and choose AM or PM with UP and DOWN. Press OK when finished, or X if you make a mistake. Special spray times:
- 99:00 sprays once an hour.
- 99:10 sprays once every 20 minutes.
- Del spray time: deletes spray times from the daily program. UP and DOWN cycle through the programmed times, OK deletes the one shown and X returns to the main menu.
- View spray times: shows the spray times in the daily program. UP and DOWN cycle through them and X returns to the main menu. The numbers in the upper left show which time you're looking at and how many are programmed: "02/05" is time 2 of 5.
- Set duration: sets how long each spray lasts, from 1 to 99 seconds.
- Set time: sets the system time. Enter the time with the number pad and choose AM or PM with UP and DOWN. Press OK when finished, or X if you make a mistake.
- Set date: sets the system date with the number pad. Press OK when finished, or X if you make a mistake.
- Statistics: opens the statistics menu.
- Service mode: used by system operators during tank refills and setup. Requires the service code or franchise code (see the service menu).
- Assign remote: sets up a remote control for the system. Hold the mist off button on the remote and the display shows its address and button number; press OK at the same time to assign the remote. An asterisk (*) means the remote is assigned. "set remote addr" means the remote hasn't been given an address yet (see setting up the remote).
- Set spray days: turns the system off on days of the week when no one will be around. UP and DOWN cycle through the days, OK toggles Y or N and X returns to the previous menu.
- Set spray months: turns the system off in months with few mosquitoes. UP and DOWN cycle through the months, OK toggles Y or N and X returns to the previous menu.
- Reset settings: resets all user settings to the factory defaults. Press OK, then OK again to answer "are you sure?". This does not reset the passwords, the empty sensor or setup data.
Statistics menu
- Tank capacity: the total number of spray seconds the system should provide. Press OK, enter the number of gallons and press OK, then enter the number of nozzles and press OK. It calculates 1 ounce per nozzle per minute. This must be set for the other statistics to be correct.
- Total tank use: total seconds sprayed since the last refill.
- Program use: the part of total use from the daily programmed sprays.
- Manual use: the part of total use from "Press OK to spray" and the remote.
- Last fill: the date the tank was last refilled.
- Should fill by: the approximate date the tank will be empty, based on tank capacity, total use to date, spray duration, number of zones, spray times per day, spray days of the week, spray months of the year and an estimate of manual use.
- Tank empty date: the date the tank went empty, or "N/A" if it hasn't been empty since the last fill.
- Last tank held: total seconds sprayed the last time the tank went empty, or "N/A". It isn't updated when the total is under 1,000 seconds, because the empty sensor was most likely moved during filling.
- Firmware version: the version of code running on the unit.
Service menu
- Filled tank: press OK to reset the tank sensor and statistics. "**TANK IS FULL**" shows when the tank has been filled recently. Select this after every fill.
- Set SERV code / Set FRAN code: change the access codes. The service code (SERV) is generally the only code the installer should use. The franchise code (FRAN) lets the franchise owner reset the service code if there's a problem or it's lost (see access codes).
- Hit zone num or OK to test spray: sprays without affecting the statistics, for testing and checking for leaks. It sprays for 4 minutes or until stopped. OK sprays zone 1; number keys spray the other zones.
- Remote type: changes what the remote's buttons do (see setting up the remote).
- System zones: the number of zones the system controls, 1 or 2.
- Drain time: how long each zone de-pressurizes before the next zone sprays. Multi-zone systems only.
- Set sensor types: sets each connected sensor to normally open (NO) or normally closed (NC). UP and DOWN select the sensor, OK or 0–9 toggles it and X exits.
Setting up the remote
- Open the small panel on the back of the remote with a paper clip.
- With the paper clip, flip a few of the tiny switches to set the address. Any address except 0 works; flipping them randomly makes it less likely your remote matches a neighbor's.
- Put the panel back on.
To change the remote type for a special configuration, enter service mode, scroll to Remote type and enter the new type:
- 0: default, with spray all zones and system suspend buttons
- 1–4: the 1st, 2nd, 3rd or 4th row of buttons sprays all zones
- 5: the top 4 buttons control zones 1 and 2
- 6: the bottom 4 buttons control zones 1 and 2
- 7: spray all zones, plus on/off for zones 1 and 2
- 8: spray all zones, system suspend, plus on/off for zones 1 and 2
By assigning the same remote to several systems with different remote types, one remote can control up to 4 systems (2 zones each) or 4 zones independently.
Shortcut buttons
Holding these panel buttons for at least 3 seconds performs a shortcut, useful for service providers setting up several units or homeowners who want to turn the system off:
- 0: the service operator enters the code and the tank is reset. Used when refilling.
- 1: add spray times.
- 2: delete spray times.
- 3: test mode. Press X to exit.
- 4: set duration.
- 5: set time.
- 6: set date.
- 7: statistics menu.
- 8: service menu.
- 9: hold with a button on the remote to assign the remote.
- X: shuts the system off. Press OK to turn it back on.
Access codes
Don't change the franchise code unless you have to. If it's lost, you may have to call in for an unlock code.
Refilling procedure
- Unplug the system.
- Carefully remove the tank cover and fill and mix the insecticide.
- Replace the tank cover.
- Plug the system in.
- If the tank had gone completely empty, check the statistics menu to see whether the tank capacity estimate needs adjusting.
- Hold 0 for 3 seconds to enter quick refill mode.
- Enter the user or franchise password and press OK.
- The empty light should go off, and total use should return to 0 seconds.
Troubleshooting: my system won't spray
Press X a few times to make sure you're looking at the main message, then check:
- "TANK EMPTY" or "CODE REQUIRED": the tank is probably empty. Call your service provider to schedule a refill.
- "SYSTEM OFF": the system was suspended by the remote or by holding X for 3 seconds. Press OK to return to normal operation.
- "spray hold" with a countdown: built-in motor protection to prolong the life of the pump. Wait until the countdown reaches 0 and try again.
- Check that the time and date are set correctly.
- Make sure the system hasn't been turned off for the current month or day of the week with Set spray days and Set spray months.
More help: the troubleshooting guide.