This guide covers the Mosquito-Pro™ MCU1001A controller, from the controller manual. Other brands work differently; if you're not sure what you have, call us at (832) 778 - 6366.
My system won't spray
Press X a few times to make sure you're looking at the main message, then check what the display says.
"TANK EMPTY" or "CODE REQUIRED"
The tank is probably empty. Call your service provider to schedule a refill.
"SYSTEM OFF"
The system has been suspended, either by the remote or by holding X for 3 seconds. Press OK to return to normal operation.
"spray hold" with a countdown
The controller has built-in motor protection to prolong the life of the pump. Wait until the countdown reaches 0, then try again.
If the display shows none of these:
- Check the time and date. Scheduled sprays run on the controller's clock. Fix them with Set time and Set date in the main menu, or hold 5 (time) or 6 (date) for 3 seconds.
- Check spray days and spray months. Make sure spraying hasn't been turned off for the current day of the week or month, with Set spray days and Set spray months in the main menu.
- Check the spray times. View spray times in the main menu shows each programmed time; "02/05" means you're looking at time 2 of 5.
- Try a manual spray. From the main menu, "Press OK to spray" sprays for the set duration. X stops it early.
It runs, but doesn't mist properly
Check the nozzle tips and tubing for clogs and visible leaks. If that doesn't fix it, call us at (832) 778 - 6366. Common causes include pressure problems, pump or motor issues and controller programming, and we can walk you through it or send a technician.
The remote doesn't work
- Go to Assign remote in the main menu and hold the mist off button on the remote. The display should show the remote's address and button number.
- If it shows "set remote addr", the remote hasn't been given an address. Open the small panel on the back of the remote with a paper clip, flip a few of the tiny switches to any address except 0, and close the panel.
- Hold the remote button and press OK at the same time to assign it. An asterisk (*) means the remote is assigned. Holding 9 for 3 seconds while pressing a remote button also assigns it.
The refill date looks wrong
- The Should fill by date depends on Tank capacity in the statistics menu. Enter the tank's gallons and the number of nozzles; it calculates 1 ounce per nozzle per minute.
- After every refill, Filled tank in the service menu (or holding 0 for 3 seconds and entering the code) must be selected to reset the tank sensor and statistics.
- Last tank held isn't updated when it's under 1,000 seconds, because the empty sensor was most likely moved during filling.
Turning the system off
Hold X for 3 seconds to shut the system off, and press OK to turn it back on. To skip certain days or months automatically, use Set spray days and Set spray months instead.
Still not working?
Call us at (832) 778 - 6366. We repair Mosquito-Pro™ systems and many other brands, and our existing system maintenance covers inspections, repairs and refills.